L50CD-SB93A2-01 0.1A Micro Switch for Furnace
Toneluck Sail Switch Short Description L50CD-SB93A2-01 is the Toneluck sail switch that can be used in…
Blower door interlocks that cut power when a furnace panel is removed.
A furnace door safety switch is a mechanical interlock mounted on the blower or burner compartment. When the service door is removed, the switch opens the control circuit so the furnace cannot run with the compartment exposed. When the door is replaced, the actuator closes the contacts and restores normal operation.
Because the switch is part of a safety chain, the priorities are consistent actuation, resistance to dust and heat, and a contact rating that matches the furnace control circuit. A worn or misaligned switch can cause intermittent no-heat calls or, worse, allow operation with the door open.
| Contact rating | 1A to 16A (model dependent) |
|---|---|
| Voltage | 125/250VAC, 12/24VDC options |
| Contact form | SPST normally open/closed, SPDT |
| Actuation | Plunger, lever or door-actuated button |
| Operating temperature | -40°C to +85°C standard; high-temperature versions available |
| Mechanical life | Up to 500,000 cycles minimum on selected ranges |
| Approvals | UL, cUL, ENEC, CE, CQC |
Toneluck also supplies pressure switches used for draft proving and sail switches used to confirm airflow in the flue. Sourcing the door interlock, pressure switch and airflow switch from one manufacturer simplifies qualification and keeps approval documents consistent.
These Toneluck models are commonly specified for this application. Ratings, actuators and terminals can be adapted for OEM programmes.
Toneluck Sail Switch Short Description L50CD-SB93A2-01 is the Toneluck sail switch that can be used in…
PS160 Air Pressure Switch PS160 furnace air pressure switch is a low-pressure & negative switch, its…
Oven Door Light Switch for KitchenAid, Whirlpool, Kenmore, Estate D2 Series Door Switch Product name: D211M-EA1-01…
Toneluck D6 Dryer Door Switch is an SPDT 10A switch used in dryers, washing machines, and…
The S12AAF102-S01 is an SPDT with 3 Terminal and 5E5 long life 40T125 high-temperature straight lever…
2 Terminal Micro Switch Short Description The V38 2 terminal micro switch is a rare type…
A door switch confirms that the blower or burner compartment is closed. A pressure switch confirms that the fan is moving air or that draft is present. Both are part of the furnace safety chain but sense different conditions.
It depends on the control design. Many furnaces use a normally open switch that closes when the door is fitted; others interrupt the circuit when the door is removed. Match the original circuit and always test the safety function after replacement.
A replacement must match the mounting, actuator travel, contact form and electrical rating of the original. Contact us with the original part number or a photo and dimensions, and we will identify the closest Toneluck model.
The switch must carry the control-circuit current with margin, especially for inductive loads such as gas valves and relays. Typical furnace door switches are rated between 1A and 16A at 125/250VAC.
Yes. High-temperature micro switches are available for locations close to the burner or heat exchanger.
Yes. Provide the target specification and we will send samples for testing before a production order.
Send us your drawings, ratings and volume. We will recommend the closest platform and quote a custom sample.